{"id":202,"date":"2016-06-21T11:20:43","date_gmt":"2016-06-21T09:20:43","guid":{"rendered":"http:\/\/blog.fraunhofer.de\/Innovation4e\/en\/?p=202"},"modified":"2016-08-24T17:02:10","modified_gmt":"2016-08-24T15:02:10","slug":"callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg","status":"publish","type":"post","link":"https:\/\/blog.innovation4e.de\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/","title":{"rendered":"Callab PV Cells: 30 Years of High Precision Measurement in Freiburg"},"content":{"rendered":"<p>If you want to know the efficiency of a solar cell exactly, it is likely that you will land in Freiburg, Germany sooner or later. For 30 years high-precision reference solar cells \u2013 and for almost 25 years reference modules \u2013 have been measured at the CalLab PV Cells of Fraunhofer ISE. Researchers, producers and plant operators order calibrated cells to have their own benchmarks. It is comparable to the \u201cmodel meter\u201c in Paris: If you have one copy of that standard, you can always check your in-house measurement equipment against it. Since CalLab PV Cells is internationally renowned and certified, any research value published with the certificate of Fraunhofer ISE will automatically be more credible. \u00a0CalLab PV Cells was founded in 1986 with three co-workers. Today 30 employees calibrate about 2,500 solar cells and 5,000 solar modules each year.<\/p>\n<p><!--more--><\/p>\n<h2>How do they calibrate solar cells?<\/h2>\n<p>CalLab PV Cells first measures the area of the cell with a laser device and its spectral response with a filter monochromator. With that information the solar simulator can be set to standard testing conditions \u2013 AM1.5 standard spectrum, 1000 W\/m<sup>2<\/sup> irradiance and 25 \u00b0C cell temperature. The cell is mounted on a temperature-controlled measurement chuck, vacuum-contacted without shading. A current-voltage characteristic (I-V curve) is measured from which the short circuit current, open circuit voltage, fill factor and efficiency are extracted. About 90% of the calibration requests come from industry. Typically a manufacturer sends five selected specimens from his production line for calibration. He makes 100 copies from these reference samples for monitoring his production line of about 3,600 cells per hour. After one year, he will have the calibration checked again.<\/p>\n<h2>The long line to a primary standard<\/h2>\n<p>To calibrate is to compare a test object to a known reference which serves as a benchmark. The benchmark itself can be traced to a national standard, a so-called \u201cprimary reference\u201d, which is kept in Germany at PTB (Physikalisch-Technische Bundesanstalt) in Braunschweig. The PTB provides CalLab PV Cells with primary reference cells, which are used to produce encapsulated secondary reference cells. For industry CalLab PV Cells produces unencapsulated work reference cells. Since 1986, CalLab PV Cells and PTB have been working together closely. CalLab PV Cells is accredited as an official calibration lab or \u201cDeutsche Akkreditierungsstelle GmbH (<em>DAkkS<\/em>) \u00a0by PTB.<\/p>\n<h2>Precision as a Passion<\/h2>\n<p>The physicist Dr. Jochen Hohl-Ebinger, Head of Team CalLab PV Cells, speaks of his passion: \u201dWe want to calibrate every device which yields a current when irradiated by the sun\u201c. He and his colleagues from the other calibration laboratories have to keep pace with developments in technology. A whole zoo of cell devices has passed through his hands \u2013 with gloves of course: Silicon, III-V, II-VI, multi-junction, various thin film technologies as well as organic, dye, concentrator solar cells. The cell dimensions range from one square millimeter to 6 inch cells and even small concentrator modules. Despite the varying cell technologies and sizes, he and his colleagues have been able to find a fitting technological solution for the measurement of each type. \u00a0Quality assurance is also key. Some months ago Jochen Hohl-Ebinger and his boss Dr. Wilhelm Warta, Department Head Characterization and Simulation \u00a0went to an competitive internationally renowned calibration lab because significant \u2013 i.e. 0.5 % &#8211; measurement differences on standard silicon solar cells were apparent. All three researchers discussed every bit of the apparatus and code until they agreed again.<\/p>\n<figure id=\"attachment_325\" aria-describedby=\"caption-attachment-325\" style=\"width: 650px\" class=\"wp-caption aligncenter\"><a class=\"gridlove-popup-img\" href=\"https:\/\/websites.fraunhofer.de\/blog_innovation4e_de\/wp-content\/uploads\/2016\/06\/Maenner-Gruppe_sw.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-325 size-large\" src=\"http:\/\/blog.fraunhofer.de\/Innovation4e\/wp-content\/uploads\/2016\/06\/Maenner-Gruppe_sw-650x435.jpg\" alt=\"Maenner-Gruppe_sw\" width=\"650\" height=\"435\" srcset=\"https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Maenner-Gruppe_sw-650x435.jpg 650w, https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Maenner-Gruppe_sw-300x201.jpg 300w, https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Maenner-Gruppe_sw-768x514.jpg 768w, https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Maenner-Gruppe_sw-370x248.jpg 370w, https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Maenner-Gruppe_sw-270x181.jpg 270w, https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Maenner-Gruppe_sw-740x495.jpg 740w, https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Maenner-Gruppe_sw.jpg 1840w, https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Maenner-Gruppe_sw-650x435@2x.jpg 1300w, https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Maenner-Gruppe_sw-300x201@2x.jpg 600w, https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Maenner-Gruppe_sw-768x514@2x.jpg 1536w, https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Maenner-Gruppe_sw-270x181@2x.jpg 540w, https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Maenner-Gruppe_sw-740x495@2x.jpg 1480w\" sizes=\"auto, (max-width: 650px) 100vw, 650px\" \/><\/a><figcaption id=\"caption-attachment-325\" class=\"wp-caption-text\">Klaus Heidler (second from right) and colleagues from CalLab. \u00a9Fraunhofer ISE<\/figcaption><\/figure>\n<h2>Trust is good, control is better<\/h2>\n<p>To get rid of artefacts and errors, the four most renowned calibration laboratories of the world undertake round robin tests on a regular basis to achieve measurement uncertainties between 0.7 and 2%. Besides quality control, \u00a0data confidentiality is an important aspect for the lab\u2019s customers. For Fraunhofer ISE itself confidentiality is also crucial, since the institute develops solar cell technology on its own, thus competing in some areas with the CalLab PV Cells customers. Therefore, there is an impenetrable barrier set up between CalLab PV Cells and research technology. Nobody, besides the head of the CalLab PV Cells and some selected staff, knows where the test cells come from and how they perform. This is also true for Jochen\u2019s supervisor, the director of the division Solar Cells \u2013 Development and Characterization. First in the conference talk of a competitor did his supervisor learn that his own world record efficiency had been surpassed by the competitor who claimed \u201cverified by Fraunhofer ISE\u201c. That was true. CalLab PV Cells had confirmed the world record.<\/p>\n<figure id=\"attachment_324\" aria-describedby=\"caption-attachment-324\" style=\"width: 650px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-324 size-large\" src=\"https:\/\/websites.fraunhofer.de\/blog_innovation4e_de\/wp-content\/uploads\/2016\/06\/Goetzberger_sw-650x435.jpg\" alt=\"Prof. Adolf Goetzberger, Gr\u00fcnder und Institutsleiter des Fraunhofer ISE von 1981-1993 im Kalibrierlabor. \u00a9Fraunhofer ISE\" width=\"650\" height=\"435\" srcset=\"https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Goetzberger_sw-650x435.jpg 650w, https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Goetzberger_sw-300x201.jpg 300w, https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Goetzberger_sw-768x514.jpg 768w, https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Goetzberger_sw-370x248.jpg 370w, https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Goetzberger_sw-270x181.jpg 270w, https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Goetzberger_sw-740x495.jpg 740w, https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Goetzberger_sw.jpg 1840w, https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Goetzberger_sw-650x435@2x.jpg 1300w, https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Goetzberger_sw-300x201@2x.jpg 600w, https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Goetzberger_sw-768x514@2x.jpg 1536w, https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Goetzberger_sw-270x181@2x.jpg 540w, https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/Goetzberger_sw-740x495@2x.jpg 1480w\" sizes=\"auto, (max-width: 650px) 100vw, 650px\" \/><figcaption id=\"caption-attachment-324\" class=\"wp-caption-text\">Prof. Adolf Goetzberger, founder und director of Fraunhofer ISE from 1981-1993 in the Calibration Lab. \u00a9Fraunhofer ISE<\/figcaption><\/figure>\n<h2>No two types are the same<\/h2>\n<p>Nearly every test specimen has its own catch. Take back contacted solar cells. For each contact pattern CalLab PV Cells has to design a new measurement chuck. \u00a0Although the massive copper block costs about 15,000 euros, the manufacturer, knowing the return of investment is about two weeks, is willing to pay that within a twinkle of an eye. \u00a0In a 250 MW production line, 0.5% better accuracy means 1000 euros per day! What about bifacial solar cells? Finding the best \u201cblack\u201c paint for a measurement chuck to reduce stray back light may require \u00a0a whole series of experiments. In short, there is no standard procedure to calibrate standard cells. For each new device, a new procedure with standard quality must be invented. CalLab PV Cells scientists can take advantage of their colleagues with their in-house expertise in\u00a0 solar cell technologies and measurement techniques. However, while CalLab PV Cells benefits from the technology departments, the technology departments do not benefit from CalLab PV Cells.<\/p>\n<h2>Taming Murphy<\/h2>\n<p>Murphy\u2019s law, one of the best known laws, states: \u201dAnything that can go wrong, will go wrong.\u201d You will need the investigative energy of Sherlock Holmes and the patience of a tight-rope walker to find hidden problems and to follow quality management procedures even when a long line of customers is pressing on you to deliver results. It is a large task to establish a precision measurement setup, yet the real challenge is to maintain the high quality level and ensure reproducibility even when measuring 50 different cells per week. Therefore, every step is documented and certified. There is a maintenance schedule for every digital voltmeter and power supply. Changing a light bulb can trigger a 50 hour process, which includes aging the lamp, adjusting all electrical and optical elements and measuring spectral and homogeneity characteristics anew. Only when the values of designated encapsulated reference cells can be reproduced reliably, will the new lamp be cleared for CalLab PV Cells calibrations.<\/p>\n<h2>Calibration menu<\/h2>\n<p>Fees for standard cell calibrations start at 470 euros and encompass area, linearity, spectral response, I-V characteristics. Many other measurement services like temperature gradient or different irradiance levels are also available. The three calibration laboratories at Fraunhofer ISE cover the whole spectrum of photovoltaic generators from flat plate or concentrator modules to sophisticated multi-junction devices. Because the demand keeps increasing, CalLab PV Cells is preparing a new laser-based high speed calibration procedure which promises even more measurement precision.<\/p>\n<blockquote>\n<h2>More stuff<\/h2>\n<ul>\n<li>Detailed description of CalLab PV Cells features:<br \/>\n<a href=\"https:\/\/www.ise.fraunhofer.de\/en\/service-units\/callab-pv-cells-callab-pv-modules\" target=\"_blank\">https:\/\/www.ise.fraunhofer.de\/en\/service-units\/callab-pv-cells-callab-pv-modules<\/a><\/li>\n<li>Press release: Fraunhofer ISE CalLab PV Cells Celebrates 30th Jubilee:<br \/>\n<a href=\"https:\/\/www.ise.fraunhofer.de\/en\/press-and-media\/press-releases\/press-releases-2016\/fraunhofer-ise-callab-pv-cells-celebrates-30th-jubilee\">https:\/\/www.ise.fraunhofer.de\/en\/press-and-media\/press-releases\/<\/a><\/li>\n<\/ul>\n<\/blockquote>\n","protected":false},"excerpt":{"rendered":"<p>If you want to know the efficiency of a solar cell exactly, it is likely that you will land in Freiburg, Germany sooner or later. For 30 years high-precision reference solar cells \u2013 and for almost 25 years reference modules \u2013 have been measured at the CalLab PV Cells of Fraunhofer ISE. Researchers, producers and [&hellip;]<\/p>\n","protected":false},"author":10,"featured_media":323,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[55],"tags":[67,87,68,69,70],"coauthors":[],"class_list":["post-202","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-energy-utilization","tag-calibration","tag-callab-pv-cells-en","tag-lab","tag-solar-cells","tag-solar-modules"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.8 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Callab PV Cells: 30 Years of High Precision Measurement in Freiburg | Innovation4E<\/title>\n<meta name=\"description\" content=\"For 30 years high-precision reference solar cells \u2013 and for almost 25 years reference modules \u2013 have been measured at the CalLab PV Cells of Fraunhofer ISE.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Callab PV Cells: 30 Years of High Precision Measurement in Freiburg | Innovation4E\" \/>\n<meta property=\"og:description\" content=\"For 30 years high-precision reference solar cells \u2013 and for almost 25 years reference modules \u2013 have been measured at the CalLab PV Cells of Fraunhofer ISE.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/\" \/>\n<meta property=\"og:site_name\" content=\"Innovation4E\" \/>\n<meta property=\"article:published_time\" content=\"2016-06-21T09:20:43+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2016-08-24T15:02:10+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/wp-content\/uploads\/2016\/06\/30_Jahre_Callab.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1536\" \/>\n\t<meta property=\"og:image:height\" content=\"700\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Klaus Heidler\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Klaus Heidler\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/\"},\"author\":{\"name\":\"Klaus Heidler\",\"@id\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/#\/schema\/person\/5772ccbf7b422f9bae88186a50476f9b\"},\"headline\":\"Callab PV Cells: 30 Years of High Precision Measurement in Freiburg\",\"datePublished\":\"2016-06-21T09:20:43+00:00\",\"dateModified\":\"2016-08-24T15:02:10+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/\"},\"wordCount\":1223,\"commentCount\":1,\"publisher\":{\"@id\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/#organization\"},\"image\":{\"@id\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/30_Jahre_Callab.jpg\",\"keywords\":[\"calibration\",\"CalLab PV Cells\",\"lab\",\"solar cells\",\"solar modules\"],\"articleSection\":[\"energy utilization\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/\",\"url\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/\",\"name\":\"Callab PV Cells: 30 Years of High Precision Measurement in Freiburg | Innovation4E\",\"isPartOf\":{\"@id\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/30_Jahre_Callab.jpg\",\"datePublished\":\"2016-06-21T09:20:43+00:00\",\"dateModified\":\"2016-08-24T15:02:10+00:00\",\"description\":\"For 30 years high-precision reference solar cells \u2013 and for almost 25 years reference modules \u2013 have been measured at the CalLab PV Cells of Fraunhofer ISE.\",\"breadcrumb\":{\"@id\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/#primaryimage\",\"url\":\"https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/30_Jahre_Callab.jpg\",\"contentUrl\":\"https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/30_Jahre_Callab.jpg\",\"width\":1536,\"height\":700,\"caption\":\"Callab PV Cells: 30 Jahre hochpr\u00e4zise Messungen in Freiburg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Callab PV Cells: 30 Years of High Precision Measurement in Freiburg\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/#website\",\"url\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/\",\"name\":\"Innovation4E\",\"description\":\"Fraunhofer ISE Science Blog\",\"publisher\":{\"@id\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/#organization\",\"name\":\"Innovation4E\",\"url\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2018\/07\/Key_Visual_Logo_Retina.png\",\"contentUrl\":\"https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2018\/07\/Key_Visual_Logo_Retina.png\",\"width\":810,\"height\":282,\"caption\":\"Innovation4E\"},\"image\":{\"@id\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.linkedin.com\/company\/fraunhofer-institut-f-r-solare-energiesysteme-ise\/\",\"https:\/\/bsky.app\/profile\/fraunhoferise.bsky.social\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/#\/schema\/person\/5772ccbf7b422f9bae88186a50476f9b\",\"name\":\"Klaus Heidler\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/#\/schema\/person\/image\/66cc8be9f501ad46f492345ff2ea42fa\",\"url\":\"https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2018\/06\/Klaus_Heidler_80px.jpg\",\"contentUrl\":\"https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2018\/06\/Klaus_Heidler_80px.jpg\",\"caption\":\"Klaus Heidler\"},\"description\":\"Dr. Klaus Heidler ist Physiker und Kommunikationstrainer in Freiburg im Breisgau. Seit Gr\u00fcndung des Instituts 1981 war er bis 1997 Forscher am Fraunhofer ISE. 1986 gr\u00fcndete er das Kalibrierlabor, das heute CalLab PV Cells hei\u00dft. 1998 verlie\u00df er das Institut und gr\u00fcndete seine eigene Firma \u201eSolar Consulting \u2013 Agentur f\u00fcr nachhaltige Kommunikation\u201c. F\u00fcr das Fraunhofer ISE schreibt er regelm\u00e4\u00dfig Artikel zur Solarenergie.\",\"url\":\"https:\/\/blog.innovation4e.de\/en\/author\/kheidler\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Callab PV Cells: 30 Years of High Precision Measurement in Freiburg | Innovation4E","description":"For 30 years high-precision reference solar cells \u2013 and for almost 25 years reference modules \u2013 have been measured at the CalLab PV Cells of Fraunhofer ISE.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"en_US","og_type":"article","og_title":"Callab PV Cells: 30 Years of High Precision Measurement in Freiburg | Innovation4E","og_description":"For 30 years high-precision reference solar cells \u2013 and for almost 25 years reference modules \u2013 have been measured at the CalLab PV Cells of Fraunhofer ISE.","og_url":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/","og_site_name":"Innovation4E","article_published_time":"2016-06-21T09:20:43+00:00","article_modified_time":"2016-08-24T15:02:10+00:00","og_image":[{"width":1536,"height":700,"url":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/wp-content\/uploads\/2016\/06\/30_Jahre_Callab.jpg","type":"image\/jpeg"}],"author":"Klaus Heidler","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Klaus Heidler","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/#article","isPartOf":{"@id":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/"},"author":{"name":"Klaus Heidler","@id":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/#\/schema\/person\/5772ccbf7b422f9bae88186a50476f9b"},"headline":"Callab PV Cells: 30 Years of High Precision Measurement in Freiburg","datePublished":"2016-06-21T09:20:43+00:00","dateModified":"2016-08-24T15:02:10+00:00","mainEntityOfPage":{"@id":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/"},"wordCount":1223,"commentCount":1,"publisher":{"@id":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/#organization"},"image":{"@id":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/30_Jahre_Callab.jpg","keywords":["calibration","CalLab PV Cells","lab","solar cells","solar modules"],"articleSection":["energy utilization"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/","url":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/","name":"Callab PV Cells: 30 Years of High Precision Measurement in Freiburg | Innovation4E","isPartOf":{"@id":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/#primaryimage"},"image":{"@id":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/30_Jahre_Callab.jpg","datePublished":"2016-06-21T09:20:43+00:00","dateModified":"2016-08-24T15:02:10+00:00","description":"For 30 years high-precision reference solar cells \u2013 and for almost 25 years reference modules \u2013 have been measured at the CalLab PV Cells of Fraunhofer ISE.","breadcrumb":{"@id":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/#primaryimage","url":"https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/30_Jahre_Callab.jpg","contentUrl":"https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2016\/06\/30_Jahre_Callab.jpg","width":1536,"height":700,"caption":"Callab PV Cells: 30 Jahre hochpr\u00e4zise Messungen in Freiburg"},{"@type":"BreadcrumbList","@id":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/2016\/06\/21\/callab-pv-cells-30-years-of-high-precision-measurement-in-freiburg\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/"},{"@type":"ListItem","position":2,"name":"Callab PV Cells: 30 Years of High Precision Measurement in Freiburg"}]},{"@type":"WebSite","@id":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/#website","url":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/","name":"Innovation4E","description":"Fraunhofer ISE Science Blog","publisher":{"@id":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/#organization","name":"Innovation4E","url":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/#\/schema\/logo\/image\/","url":"https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2018\/07\/Key_Visual_Logo_Retina.png","contentUrl":"https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2018\/07\/Key_Visual_Logo_Retina.png","width":810,"height":282,"caption":"Innovation4E"},"image":{"@id":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/fraunhofer-institut-f-r-solare-energiesysteme-ise\/","https:\/\/bsky.app\/profile\/fraunhoferise.bsky.social"]},{"@type":"Person","@id":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/#\/schema\/person\/5772ccbf7b422f9bae88186a50476f9b","name":"Klaus Heidler","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/websites.fraunhofer.de\/ise-blog-innovation4e\/en\/#\/schema\/person\/image\/66cc8be9f501ad46f492345ff2ea42fa","url":"https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2018\/06\/Klaus_Heidler_80px.jpg","contentUrl":"https:\/\/blog.innovation4e.de\/wp-content\/uploads\/2018\/06\/Klaus_Heidler_80px.jpg","caption":"Klaus Heidler"},"description":"Dr. Klaus Heidler ist Physiker und Kommunikationstrainer in Freiburg im Breisgau. Seit Gr\u00fcndung des Instituts 1981 war er bis 1997 Forscher am Fraunhofer ISE. 1986 gr\u00fcndete er das Kalibrierlabor, das heute CalLab PV Cells hei\u00dft. 1998 verlie\u00df er das Institut und gr\u00fcndete seine eigene Firma \u201eSolar Consulting \u2013 Agentur f\u00fcr nachhaltige Kommunikation\u201c. F\u00fcr das Fraunhofer ISE schreibt er regelm\u00e4\u00dfig Artikel zur Solarenergie.","url":"https:\/\/blog.innovation4e.de\/en\/author\/kheidler\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.innovation4e.de\/en\/wp-json\/wp\/v2\/posts\/202","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.innovation4e.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.innovation4e.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.innovation4e.de\/en\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.innovation4e.de\/en\/wp-json\/wp\/v2\/comments?post=202"}],"version-history":[{"count":23,"href":"https:\/\/blog.innovation4e.de\/en\/wp-json\/wp\/v2\/posts\/202\/revisions"}],"predecessor-version":[{"id":606,"href":"https:\/\/blog.innovation4e.de\/en\/wp-json\/wp\/v2\/posts\/202\/revisions\/606"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.innovation4e.de\/en\/wp-json\/wp\/v2\/media\/323"}],"wp:attachment":[{"href":"https:\/\/blog.innovation4e.de\/en\/wp-json\/wp\/v2\/media?parent=202"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.innovation4e.de\/en\/wp-json\/wp\/v2\/categories?post=202"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.innovation4e.de\/en\/wp-json\/wp\/v2\/tags?post=202"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/blog.innovation4e.de\/en\/wp-json\/wp\/v2\/coauthors?post=202"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}